Cm6200 install guide, Option programming tables cm6200, Starter system – Firstech, LLC. CM6200 User Manual

Page 18

Advertising
background image

Copyright 2009 Firstech, LLC.

Page 18

Connector 10 (CN10), 2-Pin (Pre-wired LED)

Note: Do not mistake for Thermister port.

Pin 1 Black - L.E.D negative (-) ground.

Pin 2 Black/White- L.E.D. 3V positive (+) output.

Connector 11 (CN11), 3-Pin (Pre-wired Valet/Programming Switch)

Pin 1 Gray/Black - Negative (-) ground.

Pin 2 Gray – 3V positive (+) L.E.D. output.

Pin 3 Gray – Negative (-) output.

CM6200 Install Guide

Starter System

www.firstechonline.com | www.compustar.com

Option Programming Tables CM6200

Option Group 1

Feature

Default Setting - I

Optional Setting - II

Optional Setting - III

Optional Setting - IV

1-01

Unlock before, Lock after,

starting

Off

On

Lock After Remote

Start Only

Lock After Shutdown

Only

1-02

Lock / Unlock pulse duration

0.8 sec

2.5 sec

0.125 sec

3.5 sec

1-03

Driver's priority unlock

Off

On

1-04

Double pulse unlock

Off

On

1-05

Rearm Output

After Start Shutdown

and First Lock

After Start Shutdown

and Every Lock

After Start Only

After Shutdown Only

1-06

Reservation Lock

(Manual transmissions)

Locks When Reserva-

tion Mode is Set

Does Not Lock When

Reservation is Set

Reservation Sets 10

Seconds After the Last

Door is Closed

1-07

Unlock / Disarm With Trunk

Release

Unlock, Factory Dis-

arm, and Trunk Release

Factory Disarm, Trunk

Release Only

Trunk Release Only

1-08

Passive Mode

Off

Passive locking with

Passive Arming

No Passive Locking

with Passive Arming

1-09

Ignition controlled door locks

Off

On

RPM Locks (Tach

Sensing Mode Only)

1-10

Auto Relock

(If a door is not opened within

this amount of time)

Off

30 sec

60 sec

5 min

1-11

Ignition / Accessory Out Upon

Unlock

Off

Ignition Pulse - same

timing as disarm pulse

Acc Pulse - same tim-

ing as disarm pulse

Ignition and Acc

Pulse - same timing as

disarm pulse

1-13

Double Pulse Disarm Input

Single Pulse

Double Pulse

1-14

Auto Lock Mode

(2 Way International Remotes)

Off

On

1-15

Trunk Output Timing

1 sec

0.5 sec

2 sec

Advertising