Cm6200 install guide, Starter system – Firstech, LLC. CM6200 User Manual

Page 19

Advertising
background image

Copyright 2009 Firstech, LLC.

Page 19

CM6200

Install Guide

Starter System

www.firstechonline.com | www.compustar.com

Option Group 2

Feature

Default Setting - I

Optional Setting - II

Optional Setting - III

Optional Setting - IV

2-01

Tach Sensing Method

Optimal Tach Method

Previous Tach Method

Low Threshold Tach

Method

2-02

Turbo Timer

Off

2 Min

1Min

4 Min

2-03

Diesel Timer

Wire

3~99sec (10sec De-

fault)

2-04

Trigger Start

Off

Single Pulse

Double Pulse

Triple Pulse

2-05

Cold or Hot Start with

Thermistor Assembly

Off

Cold Start

Hot Start

Cold and Hot Start

2-06

Timer Start, or, Minimum

Interval Between Cold Starts

3 Hour (4 minute

runtime, double for

Diesel)

1.5 Hour(4 minute

runtime, double for

Diesel)

Reservation (Runtime

set by 2-7) 2 Way LCD

Remotes Only

24 Hour Repeat with

Cold Starting of 2-8

(Runtime set by 2-7) 2

Way LCD Only

2-07

Remote Start Runtime

15 Min

25 Min

45 Min

3 Min

2-08

Temperature of Cold Starting

-10° C / 14° F

-20° C / -4° F

-5° C / 23° F

-15° C / 5° F

2-09

Temperature of Hot Starting

25° C / 77° F

30° C / 86° F

35° C / 95° F

40° C / 104° F

2-10

Engine Sensing

Tach

Alternator

No Connection – No

Tach Sensing

(Tachless Mode Only)

No Connection – 1.5

Second Crank

(Not for Manual Trans-

missions)

2-11

Turbo, Remote Start Runtime

Extension w/ #1 for 2 seconds

No

Yes

2-12

Crank Time

Standard

+0.2 Seconds to Crank

Time

+0.6 Seconds to Crank

Time

(-)0.2 Second Crank

Time

2-13

Timer Mode

Off

On

Option Group 3

Feature

Default Setting - I

Optional Setting - II

Optional Setting - III

Optional Setting - IV

3-01

Parking lights While Remote

Started

Constant Output

Flashing Output

Off

3-02

Dome Light output

Off

Factory Rearm

45 sec

Factory Rearm + 45

Sec

3-03

Dome Light Delay

Off

5 sec

45 sec

Auto

3-04

Starter-Kill Relay

Anti-Grind + Starter

Kill

Anti-Grind

Anti-Grind + Passive

Starter Kill

3-06

Factory Style Alarm

Off

On

3-08

Horn Output

On Double Lock Only

On Lock and Unlock

On Lock, Unlock, and

Start

On Double Lock and

Start