2-09

Temperature of Hot Starting – Works in conjunction with Options 2-05 and 2-06. See the option table for

available temperatures.

2-10

Engine Sensing – Review the “Common Procedures” section for complete explanations on the four

engine sensing modes.

2-11

Runtime Extension – This option resets the engine run countdown before the vehicle shuts off for either

the remote start or turbo timer. To reset the runtime you must hold the remote start button for 2.5 seonds

while the unit is still running. This feature is only available on select 2 Way LCD remotes.

2-12

Min. Crank Time - This option controls the minimum crank time for the remote starter. This is only used

if in extreme cold climates.

2-13

Timer Mode - This option turns the remote start timer mode on the system. This feature must also be

turned on by the remote.

3-01

Parking Lights while Remote Started - This option changes the parking light behavior during remote

start.

3-02

Dome Light Output – This option sets the timing output of the Dome Light wire on CN3.

Default 1: Off

Option 2: Factory Rearm – This system will pulse the dome light output during lock/arm.

Option 3: 45 second Dome Light Output – activates the dome light for 45 seconds upon unlock/disarm.

Option 4: This is a combination of 2 and 3.

3-03

Dome Light Delay – This option is used when connecting the door trigger input to the vehicles dome

light circuit. It delays the door trigger input to prevent the door open icon displaying on 2 Way remotes

upon lock/arm.

3-04 Starter-Kill – This option determines the mode of the anti-grind/starter-kill relay.

Default 1: Anti-grind + starter-kill

Option 2: Anti-grind only (no starter-kill)

Option 3: Anti-grind + passive starter-kill: starter-kill activates in 45 seconds after ignition is turned off.

3-06

Factory Style Alarm - This option turns the Factory Style Alarm on or off. When this option is turned on

the control module will monitor the door trigger input and will set off the horn honk as well as page the

2 Way remote.

3-08 Horn Output - This option changes the behavior of the white horn wire during lock, unlock, and remote