2. MAINTENANCE, TROUBLESHOOTING

2-8

2.5 Alarm

Status

The alarm status log shows the latest 25 dates and times alarms were violated.

1. At the plotter display, press the DISP key four times to show the ALARM

STATUS display.

[ALARM STATUS]
EPFS

7/MAY

4:32:16

L/L

7/MAY

4:02:01

SOG

7/MAY

2:34:54

COG

6/MAY

7:09:32

HDG

3/MAY

8:00:21

ROT

19/APR

9:05:22

Alarm name,
date and time
of alarm

ALARM STATUS display

2. Use

▼ or ▲ to scroll the log.

Alarm statuses and their meanings

Alarm Status

Indication

Meaning

TX TX

malfunction

ANT

Antenna VSWR trouble. Continued operation possible.

CH1

TDMA RX1 Board trouble. TX stopped on corresponding TX
channel.

CH2

TDMA RX2 Board trouble. TX stopped on corresponding TX
channel.

CH70

DSC RX Board trouble, transmission stopped on CH70.

COG

Invalid COG data

EPFS

No data from external navigator. Continued operation
possible.

FAIL

General system failure

HDG Invalid/nonexistent

HDG

data

L/L

No L/L data

MKD

Minimum input device failure

ROT

Invalid ROT data

SOG

Invalid SOG data