2. MAINTENANCE, TROUBLESHOOTING

2-12

2.9

Restoring Default Settings

You may clear all or specific settings to start afresh with default settings. When
all data is cleared, the default settings for all items in the INIT SETTING and
SYSTEM SETTINGS sub-menus are restored. GPS data is also cleared;
however, MMSI and IMO numbers, ship’s name and call sign are not cleared.

1. Press the MENU key to open the menu.
2. Use the CursorPad to choose DIAGNOSTICS and then press the ENT key.
3. Use the CursorPad to choose MEMORY CLEAR and then press the ENT

key.

QUIT[MENU]

[MEMORY CLEAR]

MONITOR CLEAR

SET USER DEFAULT
GPS COLD START

MEMORY CLEAR sub-menu

4. Use the CursorPad to choose MONITOR CLEAR, SET USER DEFAULT or

GPS COLD START as appropriate and then press the ENT key.

MONITOR CLEAR: Restore default settings for dimmer, contrast

CPA/TCPA, key beep, audible alarm, and received
message alarm.

USER DEFAULT:

Restores all settings to default, except items in the
INITIAL SETTINGS menu (MMSI No., IMO No., ship’s
name and call sign, etc.)

GPS COLD START: Clears GPS Almanac to receive latest Almanac.

MONITOR CLEAR.

ARE YOU SURE?
YES

NO

SET USER DEFAULT

ARE YOU SURE?
YES

NO

GPS COLD START.

ARE YOU SURE?
YES

NO

MONITOR CLEAR USER DEFAULT GPS COLD START

Confirmation screens for memory clear

5. Press

◄ to choose YES and then press the ENT key.


For MONITOR CLEAR and USER DEFAULT, a beep sounds and then the
equipment restarts.