3. RADAR OPERATION


3-3

1. Press the [GAIN] key. The last-used “adjustment window” is displayed. In the

example below, the gain sensitivity adjustment window is shown. The gain
soft keys shown depend on radar source as shown below.

.250/ 319.9

°

M

.125nm
SP

H-UP

.250/ 319.9

°

M

.125nm
SP

H-UP

GAIN
ADJUST

+

359.9

°

R

0.240nm

GAIN

A/C
SEA

A/C
RAIN

FTC

RETURN

GAIN
ADJUST

+

359.9

°

R

0.240nm

GAIN

A/C
SEA

A/C
RAIN

RETURN

Model 1700 series radar Model 1800/1900 series radar

A/C AT

ON

/OFF

GAIN SENSITIVITY

¤

AUTO ROUGH

¡

AUTO MODERATE

¡

AUTO CALM

¡

MAN

0

GAIN SENSITIVITY

¤

AUTO ROUGH

¡

AUTO MODERATE

¡

AUTO CALM

¡

MAN

0

Item selected for adjustment is highlighted.

Gain adjustment soft keys

2. If the gain sensitivity window is not displayed, press the GAIN soft key to

show it.

GAIN SENSITIVITY

¤

AUTO ROUGH

¡

AUTO MODERATE

¡

AUTO CALM

¡

MAN

0

Gain sensitivity window

3. Press ▲ or ▼ to select AUTO ROUGH, AUTO MODERATE, AUTO CALM, or

MAN (manual) as appropriate. Select an AUTO option according to the sea
state.

4. For manual adjustment, rotate the [ENTER] knob to adjust. The range of

adjustment is 0-100.

5. Press the [GAIN] key on the front panel or the RETURN soft key to finish.