Computer quadscan – FOCUS Enhancements TView Quad Scan Manual User Manual

Page 30

Advertising
background image

TView QuadScan User's Manual 0092-5000-200

30

4.3.2 Connecting the QuadScan to communications devices

Slightly different connections schemes are required for RS-232 and RS-422 operation.

Figure 5 indicates the recommended connections from a DB-9 connector for RS-232 operation. Depending on the way
that the controlling port is programmed, other connections may work as well. The QuadScan has no way of handling the
RTS/CTS and DSR/DCD signals.

Figure 6 indicates the recommended connections from a DB-9 connector for RS-422 operation. In this case, a simple 9
pin to 9 pin cable will work in all cases.

Figure 5:

Recommended RS-232 Wiring

Figure 6:

Recommended RS-422 Wiring

1 DCD

3 Data

4 RTS

5 Ground

6 DSR

7 RTS

8 CTS

1 Ground

3 Data

Computer

QuadScan

1 Ground

4 TX Data +

5 TX Data -

Computer

QuadScan

1 Ground

4 RX Data +

5 RX Data -

Advertising