1.3.5 Signal Routing Capability

The A Channel of all three types of television inputs (composite, Y/C and Component) may be independently re-
routed to the B-channel enabling pass through of the A signal to the B connector.

1.3.6 Control Methods

Front Panel Keyboard
IR Remote (Supplied)
RS-232/422 (cable ordered as an Accessory)

DB-9 Male

1.3.7 Power Consumption

Desktop Unit:

13-20 VDC

20W

Unit is shipped with a 13 Volt DC power supply, center positive, 2.5 mm barrel connector (male side on the unit). At 13
V., the desktop unit consumes a maximum of 1.5 A.

Rackmount Unit:

120 V.

0.25 A.

240 V.

0.15 A.

1.3.8 Physical Size

Desktop Unit:

7.5" X 7.25" X 2.0”"

Rackmount Unit:

19.0” X 10.0” x 1.75” (rack mount brackets installed)
17.0” X 10.0” x 1.75” (rack mount brackets not installed)

1.3.9 Environmental

Desktop Unit:
Operating Temperature:

0 to 40 degrees Celsius

Storage Temperature:

-40 to 125 degrees Celsius

Humidity:

0 to 90%, non-condensing

Rackmount Unit:
Operating Temperature:

0 to 40 degrees Celsius

Storage Temperature:

-40 to 125 degrees Celsius

Humidity:

0 to 90%, non-condensing