Frymaster FLAT BOTTOM 2424G User Manual

Page 18

Advertising
background image

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-13

1.7.4.2 Replacing Direct-Spark Ignitor Assembly (Units with Electronic Ignition Only)

1. Remove the burner shield from the

burner-box slots.


2. Disconnect sense wire and ignition cable

from the ignitor.


3. Remove the mounting screw from the

ignitor mounting-bracket and remove the
ignitor.


4. Reverse the procedure to replace the

ignitor assembly. Ensure the ignitor is
properly positioned in relation to the
center burner before tightening mounting
screw.

NOTE: The above procedure is
applicable to fryers equipped with
electronic ignition systems only.



1.7.5 Removing/Replacing Blower Assembly or Air Prover Switch


1. Remove back panel. On systems with

built-in filtration, use care not to damage
the oil-return heat-tape wiring insulation
when removing backs (multi-batteried
systems after 02/03 have two-piece back
panels; remove both to access blower
assembly).






Multi-batteried systems after 02/03 have upper
and lower back panels, which must be removed
to access the blower assembly (fryer above
shown with upper back panel removed).

Ensure ignitor is properly positioned (arrow) over
the center burner prior to tightening the mounting
screw.

Advertising