Frymaster FLAT BOTTOM 2424G User Manual

Page 19

Advertising
background image

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-14

2. Remove blower assembly by removing

four screws (two screws securing the flue
outlet to the firebox, and two screws
securing the blower inlet housing to the
firebox). Pull the assembly out of the slot
and lower to the side. Do not remove the
electrical connections at this time.


3. Replacing air prover switch:


Pressure switch:
Remove junction box
cover and mark and disconnect wiring to
the switch. Unscrew fitting connecting
sampling tube to pressure switch, being
careful not to kink the tube. Remove two
screws from bracket that attaches pressure
switch to junction box to remove switch.
Install new pressure switch with bracket.
Reattach sampling tube and wires
removed from old switch and replace
junction box cover.

Sail switch:
Remove junction box cover,
mark and disconnect wiring to the switch.
Remove screws securing the switch to the
junction box, and then remove the switch
from the blower housing. Install new
switch, ensuring the switch flap is
correctly positioned in the blower
housing. Reattach wires removed from
old switch and replace box cover.

4. If replacing blower, remove junction box

cover, mark and disconnect each wire, and
remove conduit fitting from junction box.
Reinstall conduit fitting on new blower
and reconnect wiring. Replace box cover.



5. Reverse steps 1 – 2 to reinstall blower

assembly.








After removing screws (arrows), remove blower
assembly from firebox by pulling outward.

Blower junction box wiring. Mark wire locations
before disconnecting each wire.

Advertising