Fluke DSP-2000 User Manual

Page 183

Advertising
background image

Tests Run per Test Standard During an Autotest

C

C-5

Table C-1. Tests Run per Test Standard During an Autotest (continued)

Test Standard

1

Attenuation

ACR

Return Loss

Prop.

Delay

2

Delay

Skew

2

Coax Cables

IEEE 10BaseT

5-10 MHz

100BaseTX

16 MHz

1-80 MHz

100BaseT4

2-12.5 MHz

IEEE 802.12 4-UTP

1-15 MHz

IEEE 802.12 STP

1-100 MHz

1-100 MHz

TokenRing, 4 Mb/s

4 MHz

1-12 MHz

TokenRing,16 Mb/s, Passive

16 MHz

1-25 MHz

TokenRing,16 Mb/s, Active

16 MHz

1-25 MHz

TP-PMD

16 MHz

1-80 MHz

Twin-Ax: RJ45 pins 4, 5, S

ARCnet

Aus/NZ Class C Channel

1-16 MHz

Aus/NZ Class D Channel

1-100 MHz

1-100 MHz

Aus/NZ Class C Basic Link

1-16 MHz

Aus/NZ Class D Basic Link

1-100 MHz

1-100 MHz

All Tests

1-100 MHz

1-100 MHz

1-100 MHz

1.

2.

Test standards version 4.0.

Resistance, propagation delay, and delay skew are always measured; results appear on printed test
reports.

Pass/Fail result given.

Pass/Warning result given.

Results within the accuracy specifications of the test tool are marked with an asterisk.

NEXT test is run but not displayed. Results are used to calculate ACR.