Fluke DSP-2000 User Manual
Page 183
Tests Run per Test Standard During an Autotest
C
C-5
Table C-1. Tests Run per Test Standard During an Autotest (continued)
Test Standard
1
Attenuation
ACR
Return Loss
Prop.
Delay
2
Delay
Skew
2
Coax Cables
IEEE 10BaseT
■
5-10 MHz
100BaseTX
■
16 MHz
■
1-80 MHz
100BaseT4
■
2-12.5 MHz
■
■
IEEE 802.12 4-UTP
■
1-15 MHz
■
■
IEEE 802.12 STP
■
1-100 MHz
■
1-100 MHz
■
TokenRing, 4 Mb/s
■
4 MHz
■
1-12 MHz
TokenRing,16 Mb/s, Passive
■
16 MHz
■
1-25 MHz
TokenRing,16 Mb/s, Active
■
16 MHz
■
1-25 MHz
TP-PMD
■
16 MHz
■
1-80 MHz
Twin-Ax: RJ45 pins 4, 5, S
ARCnet
Aus/NZ Class C Channel
■
1-16 MHz
❒
Aus/NZ Class D Channel
■
1-100 MHz
■
1-100 MHz
❒
Aus/NZ Class C Basic Link
■
1-16 MHz
❒
Aus/NZ Class D Basic Link
■
1-100 MHz
■
1-100 MHz
❒
All Tests
■
1-100 MHz
■
1-100 MHz
■
1-100 MHz
❒
❒
1.
2.
■
❒
Test standards version 4.0.
Resistance, propagation delay, and delay skew are always measured; results appear on printed test
reports.
Pass/Fail result given.
Pass/Warning result given.
Results within the accuracy specifications of the test tool are marked with an asterisk.
NEXT test is run but not displayed. Results are used to calculate ACR.