Fluke DSP-2000 User Manual

Page 75

Advertising
background image

Autotest

The Autotest Report

3

3-27

Mukilteo Cable Co. Test Summary: PASS

SITE: World Technology Ctr. Cable ID: Rm16COAX34

OPERATOR: Mike Marshall Date / Time: 01/07/97 10:50:12am

NVP: 80.0% FAULT ANOMALY THRESHOLD: 10% Test Standard: Coax Cables

FLUKE DSP-2000 S/N: 6680915 Cable Type: 10Base2 (50 Ohms)

Software Version: 3.29

Standards Version: 3.06

Impedance (ohms), Limit 42-58 49

Length (ft), Limit 607 No Reflection

Prop. Delay (ns) No Reflection

Resistance (ohms), Limit 48.0-65.0 50.5

gc17f.eps

Figure 3-10. Autotest Report for Coaxial Cable

MUKILTEO CABLE CO.

Cable ID: Date / Time: SITE: Length(ft):

RM1CBL1 01/06/97 09:51:46am MOUNTAIN REAL ESTATE 77 PASS

RM1CBL2 01/06/97 09:56:53am MOUNTAIN REAL ESTATE 98 FAIL

RM2CBL1 01/06/97 10:00:44am MOUNTAIN REAL ESTATE 77 PASS

RM2CBL2 01/06/97 10:01:50am MOUNTAIN REAL ESTATE 120 PASS

RM2CBL3 01/06/97 10:04:16am MOUNTAIN REAL ESTATE 99 PASS

Total Length: 471

gc18f.eps

Figure 3-11. Autotest Report Summary