Fluke DSP-2000 User Manual

Page 64

Advertising
background image

DSP-100/2000

Users Manual

3-16

Pressing

@ View Plot produces the ACR plot screen. Figure 3-5 shows an

example of the screen and Table 3-7 describes the items on the screen.

6

5

4

3

2

1

gc12c.eps

Figure 3-5. The ACR Plot Screen

Table 3-7. Items on the ACR Plot Screen

Item

Description

1

The cable pairs relevant to the plot.

2

Frequency range in MHz of the ACR test.

3

Margin is the difference between the limit and measured values plotted at the cursor’s
position. Use

L

R

to move the cursor left or right. If you move the cursor beyond the highest

test frequency specified by the selected test standard, the readout shows the ACR value at
the cursor’s position.

4

The ACR limits, as defined by the selected test standard.

5

Decibels of ACR for the cable pair.

6

The measured ACR for the cable pairs.

Advertising