Fluke DSP-2000 User Manual

Page 81

Advertising
background image

Running Individual Tests

When to Use a Remote Unit

4

4-5

1.

If you are using a DSP-100 main unit as the remote, turn the remote unit’s
rotary switch to SMART REMOTE. If you are using a smart remote unit, turn
its rotary switch to ON.

2.

Use a 2m patch cable of the correct impedance to connect the remote to the far
end of the cable link.

3.

On Model DSP-100, remove any cable connected to the test tool’s BNC
connector.

4.

Turn the rotary switch on the main unit to SINGLE TEST.

5.

Use a 2m patch cable of the correct impedance to connect the test tool to the
near end of the cable link. On Model DSP-2000, connect to the CABLE TEST
jack.

6.

Use

U D to highlight the test you want to run.

7.

Press

E to start the highlighted test.

Note

If a remote is required for the test, but is not connected, the test tool
displays the message

SCANNING FOR REMOTE and does not

run the test until a remote is connected.

If the calibration message appears, refer to “Calibrating the Test
Tool” in Chapter 6 for complete calibration instructions.

Advertising
This manual is related to the following products: