Frymaster Dean FPHD User Manual

Page 30

Advertising
background image

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-25

1.7.8 Replacing the Frypot

(cont.)


19. If the fryer is equipped with drain-valve microswitches, mark the wires and microswitch

terminals, then disconnect wires from the switch. Secure the wires to prevent damage when
frypot is removed.















20. Remove the drain valve handle by loosening

the drain valve nut and removing attached
hardware. Depending on placement and
configuration, the valve may be turned in a
different direction than pictured.









21. Remove the pilot assembly from the frypot.


- If trailing pilot, disconnect the pilot supply

line from the trailing pilot valve on the
burner manifold.

Remove the mounting screw(s) to detach the pilot
assembly from the pilot bracket.

Remove the drain valve nut and attached

hardware.

Remove the pilot assembly from the pilot bracket
on the frypot.

Left: Microswitch wires marked for removal (ensure microswitch
terminals are marked the same as the wires removed). Right:
Microswitch mounted to drain valve.

Advertising