HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-36

1.9 Troubleshooting

Guides


The following troubleshooting guides are intended to assist service technicians in quickly isolating
the probable causes of equipment malfunctions by following a logical, step-by-step process.

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Burner will not ignite.

Light in ON/OFF switch

is not illuminated.

A. ON/OFF switch is off.

A. Turn ON/OFF switch on.

ON/OFF switch is on,

but the switch light is not

illuminated.

A. No voltage at switch.

A. Ensure line voltage is present at the

switch.

A. Drain microswitch circuit (filter-

equipped units) is open.

A. Ensure drain valve is fully closed and

microswitch is functioning. Replace
microswitch if defective.

B. Voltage is present at ON/OFF switch,

but continuity of the switch in ON
position is not "0.”

B. ON/OFF switch is defective. Replace

switch with a known working switch.

C. Continuity of thermostat is not "0"

(oil temperature is at least 15°F below
electronic thermostat setting).

C. Thermostat(s) is/are defective.

Replace defective thermostat with a
known working thermostat.

ON/OFF switch is on and

the switch light is

illuminated, but there is

no output to gas valve.

D. Gas valve is suspect.

D. Go to "No burner flame" section.