1 functional description, Gas information (altitudes of 2000 feet or less) – Frymaster Dean FPHD User Manual

Page 6

Advertising
background image

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-1

High efficiency burner and diffuser.

1.1 Functional Description


High Efficiency Decathlon (HD) Series gas fryers
contain a welded stainless steel frypot heated by gas
flames diffused evenly through tubes built into the
frypot.

Flames originate from orifices in a burner manifold
positioned beneath stamped-steel burners. The burners
are positioned in the tube openings at the front of the
frypot. The diameter of the orifices differs for natural
and LP gas as indicated in the accompanying table.

GAS INFORMATION (Altitudes of 2000 feet or less)

EQUIPMENT

PRESSURE

MODEL

INPUT

(BTU)

GAS

TYPE

ORIFICE

MM

(INCH)

ORIFICE

PART NO.

QTY

MBAR

INCH W.C.

HD50G 95

NAT

LP

2.26(#43)
1.40(#54)

810-2938
810-2939

4
4

10

27.5

4

10

HD60G 125

NAT

LP

2.26(#43)
1.40(#54)

810-2938
810-2939

5
5

10

27.5

4

10

An electromechanical gas valve regulates gas flow to the manifold. HD Series gas fryers are
equipped with either a 24V valve system. Unit configurations include either a pilot ignition system
or an electronic ignition system.