into position 6 and the white into position 7. For the left half of a dual-vat unit, the red lead goes
into position 12 and the white into position 13. NOTE: Right and left refer to the fryer as
viewed from the rear.

Rib marks Position 1

6

7

12

13

10. If disconnected in step 2, reconnect connector C6 of the wiring harness.

11. Reconnect the element springs and lower the element back down onto the basket rack.

12. Reinstall the tilt housing and back panels, reposition the fryer under the exhaust hood, and

reconnect it to the electrical power supply.

1.6 Replacing Contactor Box Components

1. Remove the filter pan and lid from the unit. Drain the frypots into an oil disposal unit (MSDU)

or other appropriate metal container.

DANGER

DO NOT drain more than one full frypot or two split frypots into the MSDU at one time.

2. Disconnect the fryer from the electrical power supply.

3. Unplug the wiring harnesses from the contactor box to be serviced.

4. Remove the two screws that secure the box in place. NOTE: If you remove the screws from

both boxes at the same time, the boxes will jam against each other and neither can be removed.

Remove these screws to dismount the left contactor box.
The right contactor box is secured in a similar manner.

Advertising