Frymaster BIPH14 series User Manual

Page 9

Advertising
background image

1-5

3. On the front of the contactor box, disconnect the 6-pin connector for the left element (as viewed

from the front of the fryer) or the 9-pin connector for the right element and pull the harness out
through the rear of the fryer. Press in on the tabs on each side of the connector while pulling
outward on the free end to extend the connector and release the element leads (see photo below).
Pull the leads out of the connector and out of the plastic wire loom.

4. Raise the element to the full up position and disconnect the element springs.

5. Remove the nuts and machine screws that secure the element to the tilt plate assembly and pull

the element out of the frypot. NOTE: Full-vat elements consist of two dual-vat elements
clamped together. For full-vat units, remove the element clamps before removing the nuts and
machine screws that secure the element to the tilt plate assembly.

6. If applicable, recover the probe bracket and probe from the element being replaced and install

them on the replacement element, then install the replacement element in the frypot, securing it
with the nuts and screws removed in Step 5.

7. Route the element leads through the wire loom to prevent chafing and press the pins into the

connector in accordance with the diagram below, then close the connector to lock the leads in
place.

1

4

2

5

3

6

1

4

2

5

3

6

7

8

9

5R 4R

6R

1R

2R

3R

Pip marks Position 1

5L

4L

6L

1L

2L

3L

8. Insert the element connector into the receptacle on the front of the contactor box, ensuring that

the latches lock.

9. If disconnected in step 2, insert the temperature probe leads into the wiring harness connector

(see illustration below). For full-vat units or the right half of a dual-vat unit, the red lead goes

Advertising
This manual is related to the following products: