Diagnostic led legend – Frymaster BIPH14 series User Manual

Page 17

Advertising
background image

1-13

1.9 Interface Board Diagnostic Chart

The following diagram and charts provide ten quick system checks that can be performed using only
a multimeter.

Meter Setting

Test

Pin

Pin

Results

12 VAC Power

50 VAC Scale

1 of J2

3 of J2

12-16 VAC

24 VAC Power

50 VAC Scale

2 of J2

Chassis

24-30 VAC

*Probe Resistance (RH)

R X 1000 OHMS

11 of J2

12 of J2

See Chart

*Probe Resistance (LH)

R X 1000 OHMS

3 of J1

2 of J1

See Chart

Hi-Limit Continuity (RH)

R X 1 OHMS

7 of J2

4 of J2

0 - OHMS

Hi-Limit Continuity (LH)

R X 1 OHMS

4 of J1

7 of J1

0 - OHMS

Latch Contactor Coil (RH)

R X 1 OHMS

8 of J2

Chassis

3-10 OHMS

Latch Contactor Coil (LH)

R X 1 OHMS

5 of J1

Chassis

3-10 OHMS

Heat Contactor Coil (RH)

R X 1 OHMS

9 of J2

Chassis

18-25 OHMS

Heat Contactor Coil (LH)

R X 1 OHMS

6 of J1

Chassis

18-25 OHMS

* Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.

Diagnostic LED Legend

CMP indicates power from 12V transformer
24

indicates power from 24V transformer

HI

(RH) indicates output (closed) from right latch
relay

HI

(LH) indicates output (closed) from left latch
relay

HT

(RH) indicates output from right heat relay

HT

(LH) indicates output from left heat relay

AL

(RH) indicates output (open) from right latch

relay

AL

(LH) indicates output (open) from left latch

relay

1

2

3

4

5

6

8

7

9

10

11

12

13

14

15

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

9

10

11

12

K1

K2

K3

K4

Left

Latch

Relay

Right

Latch

Relay

Left

Heat

Relay

Right

Heat

Relay

Test Points

J1 Left J2 Right

Diagostic LEDs

Advertising
This manual is related to the following products: