Frymaster BIPH14 series User Manual

Page 8

Advertising
background image

1-4

Probe Bracket

Probe Leads

Metal Wire Tie

If replacing a high-limit thermostat, unscrew the thermostat to be replaced. Apply Loctite

PST

567 or equivalent sealant to the threads of the replacement and screw it securely into the frypot.

6. If a temperature probe was replaced, insert the probe leads into the connector (see left

illustration below). For full-vat units or the right half of a dual-vat unit, the red lead goes into
position 6 and the white into position 7. For the left half of a dual-vat unit, the red lead goes into
position 12 and the white into position 13. NOTE: Right and left refer to the fryer as viewed
from the rear.

Rib marks Position 1

6

7

12

13

Probe Lead Positions

High-Limit Lead Positions

11

10

4

5

If a high-limit thermostat was replaced, insert the leads into the connector (see right illustration
above). For full-vat units or the right half of a dual-vat unit, the leads go into positions 4 and 5
of the connector. For the left half of a dual-vat unit, the leads go into positions 10 and 11. In
either case, polarity does not matter. NOTE: Right and left refer to the fryer as viewed from the
rear.

7. Reinstall the back panels and tilt housing to complete the installation, then reverse steps 1 and 2

to return the fryer to service.

1.5 Replacing a Heating Element

1. Perform steps 1-3 of section 1.4, Replacing a Temperature Probe.

2. On dual-vat fryers, and on full-vat fryers where the temperature probe is attached to the element

being replaced, disconnect the wire harness containing the probe wiring (connector C6). Using a
pin pusher, disconnect the probe wires from the connector.

Advertising