Test Point Pressure [kPa]

1.0

2.75

BURNER

Injector

Orifice Dia.

[mm]

Gas

Consumption

[MJ/h]

Injector

Orifice Dia.

[mm]

Gas

Consumption

[MJ/h]

Auxiliary

0.85

3.60

0.53

3.60

Semi-rapid

1.12

6.30

0.70

6.30

Triple-ring wok

1.60

12.70

0.95

11.90

FOUR FUNC

TION MODELS

GAS C

OOK

T

OP MODELS

Adjusting the minimum burner setting

Check whether the flame spreads to all burner ports when the
burner is lit with the gas valve set to the minimum position.
If some ports do not light, increase the minimum gas rate
setting. Check whether the burner remains lit even when the
gas valve is turned quickly from the maximum to the minimum
position. If the burner does not remain lit, increase the
minimum gas rate setting.
To adjust the minimum gas rate setting:

1

Turn on the burner.

2

Turn the valve to the MINIMUM position.

3

Take off the knob.

4

Using a small flat screwdriver, turn the screw (see Figs. 13 or 14)

to the correct regulation.

Note: for LPG, the regulation screw is normally tightened up.

Table for the choice of injectors

Fig. 14 Adjusting the minimum burner setting: