18

Installation instructions

FOUR FUNC

TION MODELS

CER

AMIC GLASS C

OOK

T

OP MODELS

Connecting the power supply cable

Important!

This cooker must be connected to the electricity supply only by an authorised person.

To connect the power supply cable to the cooker, it is necessary to:

1

Remove the screws that hold cover “A” behind the cooker (Fig. 19b).

2

Position the U bolts “C” onto five-pole terminal block “B” according to the diagram in Fig. 19a.

3

Feed the power supply cable through the cable clamp “D”. The supply cable must be of a

suitable size for the current requirements of the appliance; see ‘Power supply cable section’.

4

Connect the phase wires to the terminal block “B” and the earth wire to the terminal “PE” as

shown in Figs. 19a-19b.

5

Take up any slack in the cable and secure with the cable clamp “D”.

6

Replace the cover “A”.

Note: the earth wire must be left about 30 mm longer than the others.

PE

1 2 3 4 5

N (L

2

)

L

1

230-240 V~

Fig. 19b

Fig. 19a Connection diagram

B

D

PE

A

5
4
3

2

1

C

B

Voltage and power consumption


230 V~ 50 Hz 9700 W (diversity not applied)

240 V~ 50 Hz 10550 W (diversity not applied)

Power supply cable section


This cooker must be connected to the
electrical supply using V105 insulated
cable.

230-240 V~ 3 x 4 mm

2