YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-10

3.8 Safety Switches (cont.)

B. Other Fryer/Filter Switches

1. Drain Valve Microswitch: The computer

will display DRAIN OPEN when the
drain valve is opened. The computer will
lockout, preventing any cooking operation
until EXIT/COOL FILTER is pressed.






















2.

Float-Switch: Located in the frypot.

Designed as a safety switch, it deactivates
the gas valve, preventing burner ignition
until the oil level extends above the
heating tubes.




3. High-limit Reset: Located in each fryer

cabinet under the control panel. This
switch is used to reset the high-limit if
the cooking medium has reached high
temperature safety limits. The high-limit
sensor bulb is mounted inside the frypot
between the two left-most burner tubes.





High-Limit

Probe

Temperature

Probe

Frypot Front

Float

Switch


A microswitch is located on the red handle at the
drain valve.

The hi-limit reset is accessible in the fryer cabinet
under the controller.