2 fryer troubleshooting (cont.) – Frymaster COOL ZONE SERIES *8196329* User Manual

Page 44

Advertising
background image

YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7-3

7.2 Fryer Troubleshooting (cont.)

7.2.4

Frypot temperature differs
from the computer
setpoint temperature.

1. Turn fryer ON.

2. Select a product number and allow the

fryer to heat for approximately 30 minutes
to stabilize shortening temperature at
desired setpoint.

3. Place a thermometer near the temperature

sensing probe within 1 inch of the
temperature probe and approximately 3-
in. (75-mm) deep into the shortening. (see
illustration, Page 7-3).

4. Press the KFC-1 SMS computer

temperature button to check the frypot
temperature. Press the computer temperature
button twice to view setpoint temperature
for the product number chosen.


5. The thermometer temperature should be

within ±10°F (±5°C) of the KFC-1
SMS computer display temperature.

Yes: System is maintaining temperature
properly.

Advertising