Installation issues and functional problems, Gige server warning, Example 1a: ip error with multiple nics – Faber Genie M1600 User Manual

Page 105

Advertising
background image

Genie Monochrome Series-GigE Vision Camera

Troubleshooting 103

Installation Issues and Functional Problems

This section covers issues indicated by the GigE server tray icon shows a warning symbol.

GigE Server Warning Example 1a: IP error with multiple NICs

The screenshot below shows an IP conflict error due to two (or more) NICs that are all set to LLA mode. In this
case both NICs are assigned the same IP address preventing communication with any connected Genie.

• When multiple NICs are used, only one can be set to LLA mode. A second NIC connected to Genie must use

the persistent IP mode or must have a DHCP server on that subnet. The following illustration shows such a
setup.

Ho
st C

omp
ute
r

NIC 1

NIC 2

NIC n

LLA Mode (only 1 NIC)

LLA Mode (error)

Persistence Mode - OK

DHCP Server

Software

DHCP Server

Hardware

DHCP Options

• For more information see

"

Multiple Camera Issues

" on page 113

,

"

Using Genie with Ethernet Switches

" on

page 17

, and

"

IP Configuration Mode Details

" on page 77

.