114 Troubleshooting

Genie Monochrome Series-GigE Vision Camera

Camera Exposure Issues

No camera exposure when expected.

• Verify by using the camera in free-running mode. Do not use external trigger mode when testing a camera

setup.

• If using free-running mode, verify that the exposure period is set to the maximum possible for the set frame

rate.

• Load factory default from the Power-up Configuration in CamExpert. This will reset the camera to its

nominal acquisition rate.

Camera is functional but frame rate is lower than expected.

• Verify Ethernet link speed. If the LAN connection is limited to 100 Mbps, the monochrome Genie frame

rate maximum will be around 30 fps for a 640x480 exposure. Higher resolution Genie models would have
even lower frame rates without a Gigabit Ethernet connection.

• If using an external trigger, verify the trigger source rate and Genie parameters such as trigger to exposure

delay.

• Verify the exposure mode type is Synchronous, not Reset mode. (See

"

Synchronization Timing

" on page

46

).

Camera is functional, frame rate is as expected, but image is black.

• Verify that the lens iris is open.
• Aim the Genie at a bright light source.
• Check that the programmed exposure duration is not too short or set it to maximum. See

"

Exposure

Controls

" on page 43

.

• Using CamExpert set the Genie to output its internal pattern generator. This step is typically done for any

camera installation to quickly verify the Genie and its software package.

Advertising