Genie signal electrical details, External inputs – Faber Genie M1600 User Manual

Page 93

Advertising
background image

Genie Monochrome Series-GigE Vision Camera

Technical Specifications 91

Genie Signal Electrical Details

Power Supply (pin 2): +12V DC nominal.

Operating tolerance +10% to –10%.
Over voltage and reverse voltage protection circuit built in. The protection circuit is reset by shutting down or
disconnecting the power supply.

• The 12-pin Hirose male connector shell and cable shield should connect to the supply earth ground to improve

EMI shielding.

External Inputs

• Opto-coupled (2V to 12V, 2mA minimum) with internal current limit.
• RS422 or TTL signal type.
• Used as trigger or integration control.
• External signal polarity selected via configuration parameter.
• User programmable debounce time from 1 to 255µs.
• See

"

Input Controls via Sapera LT or GenICam Applications

" on page 50

.

Trigger

Debounce

IN

3.3V

Genie

example

TTL external

device

4.7K

Fairchild

HMHA281R

.01µf

680

IN+

IN-

Hirose 12

connector

V+

Event

Signal

Buffer

driver

example

74HC244

External Input Detail with an Example Signal Driver

The opto-coupler is typically a Fairchild HMHA281 with the following characteristics.

Input Electrical Parameter Description

Value

Voltage threshold to turn OFF

0.8 V

Voltage threshold to turn ON

2 V

Minimum input current to turn ON

2 mA

Maximum input current

50 mA

Minimum input pulse width to turn ON

30 us

Maximum input voltage

13 V

Advertising
This manual is related to the following products: