Genie Monochrome Series-GigE Vision Camera

LUTFormat
(dependent on camera model)

RO

ENUM

Mono 8 - Unsigned = 16844800
Mono 8 - Signed = 285280256
Mono 9 - Unsigned = 16779520
Mono 9 - Signed = 285214976
Mono 10 - Unsigned = 16779776
Mono 10 - Signed = 285215232
RGB = 1124075520

TriggerSource

RW

ENUM

Input 1 = 0
Input 2 = 1
Software = 2

OutputSelectorOutput_1

RW

ENUM

Open = 0
Close = 1
Strobe On: Start of Exposure = 2
Pulse On: Valid Trigger = 4
Pulse On: Invalid Trigger = 5
Pulse On: Start of Readout = 6
Pulse On: End of Readout = 7
Pulse On: End of Acquisition = 8
Pulse On: Input 1 = 9
Pulse On: Input 2 = 10

OutputSelectorOutput_2

RW

ENUM

Open = 0
Close = 1
Pulse On: End of Exposure = 3
Pulse On: Valid Trigger = 4
Pulse On: Invalid Trigger = 5
Pulse On: Start of Readout = 6
Pulse On: End of Readout = 7
Pulse On: End of Acquisition = 8
Pulse On: Input 1 = 9
Pulse On: Input 2 = 10

PolarityInput_1

RW

ENUM

Active High = 0
Active Low = 1

PolarityInput_2

RW

ENUM

Active High = 0
Active Low = 1

PolarityOutput_1

RW

ENUM

Active Close = 0
Active Open = 1

PolarityOutput_2

RW

ENUM

Active Close = 0
Active Open = 1

PixelFormat RW

ENUM

Monochrome,
8-bit = 17301505 (0x1080001)
10-bit = 17825795 (0x1100003)

Power-upConfig

RW

ENUM

Factory Default = 0
Camera Configuration 1 = 1

SaveCameraConfigurationSelector

RW

ENUM

Camera Configuration 1 = 1

LoadCameraConfigurationSelector

RW

ENUM

Factory Default = 0
Camera Configuration 1 = 1

NetworkConfigurationMode

RW

ENUM

Automatic = 0
Manual = 1