Genie Monochrome Series-GigE Vision Camera

Installing the Genie Camera 25

Select NIC Advanced Configuration Properties

• From the Start menu go to Settings • Control Panel • Network Connections and select the NIC used to

connect the Genie to.

• Open the Properties for the Ethernet GigE NIC used with the Genie.
• Click the Configure button.

GigE NIC Configuration


• Click on the Advanced tab. Modify the values for Receive Descriptors and Jumbo Frames as follows.

Receive Descriptors

• Select the 'Receive Descriptors' property.
• Change the value to the largest value supported by the installed NIC. In this example the value is 2048.

GigE NIC Receive Buffers