46 • Operational Reference

Genie Monochrome Series-GigE Vision Camera

Synchronization Timing

Genie supports two types of sensor synchronization used to align the exposure to sensor timing:
• Synchronous Mode: Exposure is synchronous to the line timing of the sensor. Exposure granularity is 1µs and

the readout can be concurrent to the exposure for the fastest possible frame rate.

• Reset Mode: Timing is reset to initiate exposure of next frame. Exposure granularity is 1µs, but readout must

be sequential to exposure, reducing the maximum achievable frame rate.

Synchronous Mode

• Synchronous mode starts the exposure period aligned to the sensor horizontal line timing and the programmable

duration granularity is 1µs.

• In the case of the Genie M640, a horizontal line occurs every 31.77µs.
• Exposure duration is from a minimum of 100µs up to 4 sec.
• In this mode, sensor exposure and sensor readout of the previous frame's exposure occur simultaneously. This

allows operating the sensor up to its maximum frame rate.

• Any trigger received before the end of the exposure is ignored. The application can elect to receive messages

about ignored triggers. See

"

Events

" on page 63

.

• Since the external trigger is asynchronous with the Genie horizontal line timing, the frame exposure start is

subject to 1 horizontal line jitter.