Pulse on valid trigger event mode, Pulse on invalid trigger event mode – Faber Genie M1600 User Manual

Page 55

Advertising
background image

Genie Monochrome Series-GigE Vision Camera

Operational Reference 53

Pulse On Valid Trigger Event Mode

The Pulse On Valid Trigger event mode generates an output signal when a valid input trigger is received.

Pulse On Invalid Trigger Event Mode

This event mode generates an output signal when an invalid input trigger is received. An invalid trigger is any
trigger received while the camera is engaged in frame acquisition (exposure and readout) and cannot accept trigger
inputs. This is shown by the trigger exclusion region in the following diagram.