VenTing insTallaTion

Continued

Nail Only

Outer

Perimeter

of Flashing

Storm

Collar

Flashing

Cone

Underlap

Shingles

at Bottom

Overlap

Shingles Top

and Sides Only

Figure 13 - Flashing Installation

Installing Flashing on a Metal Roof

When installing the flashing on a metal roof,

it is required that putty tape be used between

the flashing and the roof. The flashing must be

secured to the roof using #8 x 3/4" screws and

then sealed with roof coating to prevent leak-

age through the screw holes. A roof coating

must also be applied around the perimeter of

the flashing to provide a proper seal.
Storm Collar Installation (SC2-1)

Place storm collar over pipe and slide down

until it is snug against the open edge of the

flashing (see Figure 14). Apply waterproof

caulk around the perimeter of the collar to

provide a proper seal.

Figure 14 - Storm Collar

Chimney

Pipe

Waterproof

Caulk

Storm

Collar

Flashing

Terminations/Spark Arrestor

The fireplace system must be terminated with

the listed round top or chase terminations. In

any case, refer to the installation instructions

supplied with the termination.

Secure

Termination

to Outer

Pipe with 3

Screws

RTL-10D

Level of

Flue Gas

Outlet

Stainless

Inner Flue

Pipe

Waterproof

Caulking

Storm

Collar

Flashing

Underlap

Shingles

Figure 15 - Termination

Overlap

Shingles (Top and Sides

of Flashing Base)

CAUTION: Do not seal open-

ings on the rooftop flashing. Fol-

low the installation instructions

provided with the termination

being used.

CHASE INSTALLATIONS

Instructions for chase installations are

included with the chase style termination

chosen. In a multiple chase installation, be

sure to provide adequate distance between

terminations to prevent smoke spillage from

one termination to another. Terminations be

separated a minimum of 24" center to center

and stacked at a minimum vertical height dif-

ference of 18" (see Figure 16).
Note: If a decorative shroud is to be installed,

contact the manufacturer for specifications.

24" Min.

24" Min.

18"

Min.

Typ.

Figure 16 - Multiple Chase Installation