Venting installation – FMI (V)G42H/50H User Manual

Page 7

Advertising
background image

www.fmiproducts.com

109493-01R

7

Figure 6 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

Georgian

Fireplace

66

1

/

2

"

12-12DM

12-12HT

Pipe Section

10

5

/

8

"

18-12DM

18-12HT

Pipe Section

16

5

/

8

"

24-12DM

24-12HT

Pipe Section

23

5

/

8

"

36-12DM

36-12HT

Pipe Section

34

5

/

8

"

48-12DM

48-12HT

Pipe Section

46

5

/

8

"

RLT-12D

RLT-12HT Round Termination

7

3

/

4

"*

STL-12D Square Chase-Top

with Slip Section 7" to 15"*

* The lineal gain for the terminations is mea-

sured to the flue gas outlet height.

Hemmed

End

12

3

/

8

"

Stainless

Inner Pipe

15" Galvanized

Outer Pipe

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of a

galvanized outer pipe, a stainless steel inner flue

pipe and a wire spacer. Pipe sections must be

assembled independently as chimney is installed.

When connecting chimney directly to fireplace,

the inner flue pipe section must be installed first

with lanced side up. The outer pipe section can

then be installed over the flue pipe section with

hemmed end up. Press down on each pipe sec-

tion until lances securely engage hem on fireplace

starter. The wire will assure the proper spacing

between inner and outer pipe sections.
Continue to assemble chimney sections as

outlined above, making sure that both inner and

outer pipe sections are locked together. When

installing double wall snap-lock chimney to-

gether, it is important to assure the joint between

chimney sections is locked. Check by pulling

chimney upward after locking. The chimney

will not come apart if properly locked. It is not

necessary to add screws to keep the chimney

together (exception, see Figure 9, page 9).

VenTing insTallaTion

Figure 5 - Outside Air Kit

Secure to Collars with Metal Tape,

Screws or Straps (Min. 1/4" x 20" size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Eyebrow

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

CHIMNEY PIPE

The FMI PRODUCTS, LLC chimney system

consists of 12", 18", 24", 36" and 48" snap-

lock, double-wall pipe segments, planned

for maximum adaptability to individual site

requirements. Actual lengths gained after

fitting overlaps must be taken into consider-

ation (lineal gain) and are given in the lineal

gain chart (see Figure 6). Lineal Gain is the

actual measurable length of a part after two

or more parts are connected. For Canada,

use chimney parts designated "HT".

WARNING: The opening in

the collar around the chimney at

the top of the fireplace must not

be obstructed. Never use blown

insulation to fill the chimney

enclosure.

OPTIONAL OUTSIDE AIR KIT

(MODEL AK4/AK4F)

The installation of an outside air kit should

be performed during the rough framing of

the fireplace due to the nature of it's location.

Outside combustion air is accessed through

a vented crawl space (AK4F) or through a

sidewall (AK4).

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.