3-3

3.5.5 Flexible Couplings, Connectors


If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must
use a heavy-duty, AGA design-certified commercial flexible connector. The connector must be at
least 3/4" NPT (with suitable strain reliefs) in compliance with the Standard for Connectors for
Movable Gas Appliances, ANSI Z21.69-1987 (or latest edition). Quick-disconnect devices must
comply with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41-1989
(or latest edition). DOMESTIC CONNECTORS ARE NOT SUITABLE!

If multi-unit batteries are installed on casters, the same ANSI Standards apply. In addition, some
means must be provided to limit the movement of the appliances without depending on the
connectors or associated piping.

3.6 ELECTRICAL CONNECTIONS


The wiring diagram is attached to the inside of the fryer door. Wiring diagrams are also included in
this manual for reference. Always consult the wiring diagram mounted on the fryer when
troubleshooting or repairing the fryer. YSCFC24 Series gas fryers require 120 volts, and are
equipped with a 16-3 SJT grounded flexible power cord for direct connection to a 120-volt power
supply. Amperage for each unit depends on the accessories supplied with the unit.

WARNING

(Electrical Grounding Instructions)

This appliance is equipped with a three-prong (grounding) plug for your protection

against shock hazard, and should be plugged directly into a properly grounded

three-prong receptacle. Do not cut, remove, or otherwise bypass the grounding

prong on this plug!