7 system installation instructions (cont.) – Frymaster YSCFC24 User Manual

Page 15

Advertising
background image

3-5


3.7 SYSTEM INSTALLATION INSTRUCTIONS (CONT.)


6. With the cabinets together, carefully slide the

drainpipe halfway into the rubber boot.
Connect the drain-flush and oil-return
flexlines (Fig. 4, arrow). Align the cabinet
connection holes, front and back (Fig. 4,
circle).



7. Insert bolts and install nuts loosely (Fig. 5,

arrows). Do not tighten bolts at this time.



8. When the two cabinets are properly aligned,

tighten the cabinet connection nuts and bolts
at the front and back. At the fryer front:
The bolts are located at the bottom front of
the connecting wall of the fryer and at the
control box. At the fryer back: The bolts are
located at the just inside the cabinet near the
cabinet connection holes, and at the top
inside the connecting wall of the flue box.



9. Reinstall back panels removed at the

beginning of system assembly. Ensure
panels are properly aligned, then install and
tighten the screws. Install the joiner strip
where fryer cabinets are connected.



10. Connect the oil-return heater-tape harness

(6-pin connector) at the bottom back of the
fryer (Fig. 6, arrows). Failure to do so will
result in clogged return lines after the first
filtering session.










Figure 4. Connect flexlines and align
cabinet connection holes.

Figure 5. Insert bolts, but do not tighten.

Figure 6. Connect heater-tape harness.

Advertising