Shutdown

1. Turn the fryer off.

2. Filter the cooking oil and clean the fryers (See Chapters 4 and 5).

3. Place the frypot covers on the frypots.

3.2

Operation of the Solid-State Analog Controller


NOTE: Refer to Chapter 4 of this manual for operating instructions for the built-in filtration system.

Fryers configured for the U.S. Navy are equipped with solid-state analog controllers.

1

3

4

5

6

2

7

U.S. Navy Solid-State Analog Controller

ITEM

DESCRIPTION

1

Power Switch – Controls electrical power to fryer.

2

Power-On Light – Indicates when electrical power to fryer is ON.

3

Heating Mode Light – Indicates when heating element is ON.

4

Trouble Light – Indicates over high-limit or problem in heat control circuitry.

5

Thermostat Control Knob – Sets desired frying temperature.

6

Hi-Limit Test Switch – Tests high-limit thermostat.

7

Second Hi-Limit Test Light – Indicates fryer is in second high-limit test mode.


The analog controller, illustrated above, is used to adjust and maintain oil at the temperature
indicated by the thermostat knob.

The fryer has two built-in high-limit protection features. If the temperature in the frypot reaches
approximately 410°F, the controller opens the heat relay circuit, turning the elements off. If the
temperature in the frypot reaches 450

°F, a mechanical high-limit shuts off electrical power to the

elements. The operator should periodically test each of the high-limit protection features, using
the procedure at the end of this chapter, to verify that they are operating correctly.