Frymaster H22SC User Manual

Page 24

Advertising
background image

5-5

• Verify that all O-rings and seals (including those on the Power Shower and on quick-disconnect

fittings) are present and in good condition. Replace o-rings and seals if worn or damaged.

• Check filtration system integrity as follows:

− Verify that filter pan cover is present and properly installed.

− With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify

that the pump activates and that bubbles appear in the cooking oil (or that gurgling is heard from
the Power Shower port) of the associated frypot.

− Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper

functioning of each oil return valve by activating the filter pump using the lever on one of the oil
return handle microswitches. No air bubbles should be visible in any frypot (or no gurgling
should be heard from the Power Shower ports).

− Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to

350°F into the filter pan and close the frypot drain valve. Place the oil return handle in the ON
position. Allow all cooking oil to return to the frypot (indicated by bubbles in the cooking oil or,
on units with Power Showers, cessation of oil flow from the Power Shower). Return the oil
return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and
30 seconds.

Advertising
This manual is related to the following products: