Frymaster H22SC User Manual

Page 28

Advertising
background image

6-4


6.2.2 Error Messages and Display Problems

Problem

Probable Causes

Corrective Action

Controller trouble

light ON.

Oil temperature above acceptable
range or a problem with the
temperature measuring circuitry.

This in an indication of a
malfunction in the temperature
measuring or control circuitry,
including a failure of the high limit
thermostat. Determining the
specific problem is beyond the
scope of operator troubleshooting.
Shut the fryer down immediately.

Controller trouble

light ON and heating

mode light ON.

Open drain valve or problem with
latching circuits

Verify that the drain valve is fully
closed. The fryer will not function
if the drain valve is not fully
closed. If the drain valve is fully
closed, the problem is within the
latching circuitry and is beyond the
scope of operator troubleshooting.


6.2.3 Filtration

Problems

Problem

Probable Causes

Corrective Action

A. Power cord is not plugged in or

circuit breaker is tripped.

A. Verify that the power cord is

fully plugged in. If so, verify
that circuit breaker is not
tripped.

B. Pump motor has overheated

causing the thermal overload
switch to trip.

B. If the motor is too hot to touch

for more than a few seconds, the
thermal overload switch has
probably tripped. Allow the
motor to cool at least 20
minutes then press the Pump
Reset Switch.

Filter pump won't

start.

C. Blockage in filter pump.

Test: Close the drain valve and
pull the filter pan out from the
fryer. Activate the pump. If the
pump motor hums for a short time
then stops, the probable cause is
blockage of the pump itself.

C. Pump blockages are usually

caused by sediment buildup in
the pump due to improperly
sized or installed filter paper
and failure to use the crumb
screen.

(continued on following page)

Advertising
This manual is related to the following products: