8 diagnostics – Furuno CH-270 User Manual

Page 110

Advertising
background image

6. MAINTENANCE, TROUBLESHOOTING

6-6

6.8 Diagnostics

1. Press the [MENU] key to open the menu.
2. Press ▲ to choose MENU, and then press ► to choose SYS.
3. Press ▼ to choose GO TO SYS MENU.
4. Press ◄ to choose YES.
5. Choose TEST and then press ► to start the test. The lamps above the XDR switches

light alternately every second while the test display is shown. In a few moments after
pressing ► the results of the test appear.

MAIN PROGRAM NO. 0650109-**.**

RAM

: OK

ROM

: OK

VRAM

: OK

NMEA

: OK#

PANEL PROGRAM NO. 0650104-0**

TX FREQUENCY

: 180kHz

ROLL

: 10

PITCH

: 10

REMOTE CONTROL

PANEL

0 0 0

0

0

0 0 0

0

EXIT

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

127

0

0

0

0

(LED)

0

0

0

0

0

0

0

* = Item currently being tested.
# = Requires special plug to test. Nothing displayed when plug is not connected.
** = Program Version No.

TRAIN/TILT

TRAIN

MOTOR TEST

PULSES

1080

COUNT: 1
NG
0

TILT
30 > +8
+8 > 30
30 > 93
93 > 30

NG

0
0
0
0

PULSES

319
313
454
449

*

Test results

To quit the test, press the [MENU] key three times.