2. HORIZONTAL MODE

2-3

2.3 Choosing

the

Range

The [RANGE] control chooses the detection (display) range. Choose the range according
to either the fish species being searched or the depth desired. 15 ranges are available.

SEA SURFACE

Range indicated
on the screen.

BOTTOM

SEA SURFACE

Range indicated
on the screen.

BOTTOM

How to choose the range

Default horizontal mode range settings

Range No.

Meters

Feet

1 10

40

2 20

80

3 40

120

4 60

200

5 80

300

6 100

400

7 120

500

8 160

600

9 200

700

10 250

800

11 300

1000

12 400

1200

13 500

1500

14 600

2000

15 800

2500

Normally, the range is set so that the bottom is traced at the lower part of the screen (like
an echo sounder). Each time the [RANGE] control is operated the newly chosen range
briefly appears in large characters at the screen top. Range is always displayed at the top
right-hand corner of the screen.

Note 1: Unit of range measurement may be chosen from among meters, feet, fathoms,

passi/braza and Hiro (Japanese), with UNIT on the SYSTEM SETTING 1 menu.
For further details, see UNIT in paragraph 5.4.2.

Note 2: Ranges may be freely preset as desired. For further details, see paragraph 5.4.4.