3 choosing the range, 4 choosing train center – Furuno CH-270 User Manual

Page 60

Advertising
background image

3. VERTICAL SCAN MODE

3-6

3.3 Choosing

the

Range

The [RANGE] control chooses the detection (display) range, in 15 settings. Choose the
range according to either the fish species being searched or the depth desired. Each time
the control is operated the newly chosen range briefly appears in large characters at the
screen top. Range is permanently displayed at the top right-hand corner of the screen.

Default vertical scan mode range settings

Unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Meters 10 20 30 40 60 80 100

120

160

200

250

300 400 500 600

Feet 30 60 90 120 150 200

250

300

400

500

600

800 1000 1500 2000


Note 1:
Unit of range measurement may be chosen from among meters, feet, fathoms,

passi/braza and Hiro (Japanese) with UNIT on the SYSTEM SETTING 1 menu.
For further details, see UNIT in paragraph 5.4.2.

Note 2: Ranges may be freely preset as desired. For further details, see paragraph 5.4.5.

3.4 Choosing Train Center

The [TRAIN] control determines the bearing of the vertical scan beam, from 0

° to 180°.

Bearing of beam position can be found by observing the train indicator.

0

° (360°) → 6° → 12° → 18° → ... 180°

Train Indicator

Train of Vertical Scan Beam

Bow

TRAIN

Train indicator

Train indicator

STBD

FORE

AFT

Train 0

° Train 90° Train 180°

Train indicator and display

Advertising