4 sector format – FUJITSU MAT3147NC/NP User Manual

Page 40

Advertising
background image

3-6

C141-E201

Head

Track skew

Track skew

Head skew

Leading logical
sector in head p+1

Head

Figure 3.5

Track skew/head skew


The number of physical sectors (track skew factor and head skew factor) corresponding to the
skew time varies depending on the logical data block length because the track skew and the head
skew are managed for individual sectors. The IDD automatically determines appropriate values
for the track skew factor and the head skew factor according to the specified logical data block
length. The value can be read out by the MODE SENSE or MODE SENSE EXTENDED
command after the track has been formatted.


3.1.4 Sector

format

Each sector on the track consists of an ID field, a data field, and a gap field which separates them.
Figure 3.6 gives sector format examples.

SCT

PAD

SM1

PLO
Sync

G1

SCT

G2

DATA1

SM2

BCRC

DATA2

ECC

SCT

PAD

SM1

PLO
Sync

G1

SCT

G3

DATA1

SM2

DATA3

PAD G2

SM1

PLO
Sync

G1

DATA1

SM2

DATA4

Servo

BCRC

ECC

Figure 3.6

Sector format


Each sector on the track consists of the following fields: