3-7


(1)

Gaps (G1, G2, G3)

No pattern is written on the gap field.


(2) PLO

Sync

In this field, pattern X'00' in the specified length in bytes is written.


(3)

Sync Mark (SM1, SM2)

In this field, special pattern in the specified length in bytes is written. This special pattern indicates
the beginning of the data field.

(4)

Data field (DATA1-DATA4)

User data is stored in the data field of the sector. The length of the data field is equal to that of the
logical data block which is specified with a parameter in the MODE SELECT command. Any
multiple of 4 between 512 and 528 bytes can be specified as the length.

(5) BCRC

It is a 4-byte error detection code. Errors in the ID field. Single burst errors with lengths of up to
32 bits for each logical block can be detected.


(6) ECC

This is the 54 byte code that allows detection and correction of errors in the data field, which is
capable of correcting the single burst error up to 216 bits max. on the fly.


(7) PAD

In this field, pattern X'00' in the specified length in bytes is written. This field includes the
variation by rotation and circuit delay till reading/writing.