FUJITSU MAT3147NC/NP User Manual

Page 56

Advertising
background image

4-6

C141-E201

(3)

Limitation of bottom-mounting

Use all 4 mounting holes on the bottom face.

(4) Environmental

temperature

Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the disk drive. At designing the system cabinet, consider following points.

• Make a suitable air flow so that the DE surface temperature does not exceed 60°C.

• Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect

by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.

Table 4.1

Surface temperature check point

No. Measurement

point Criteria

1

Center of DE cover

60°C

2

Read channel LSI

88°C

3 VCM/SPM

Driver

92°C

4 HDC

91°C

5 MPU

91°C


1

4

5

2

3

Figure 4.6 Surface temperature measurement points

Advertising
This manual is related to the following products: