5 format capacity, 2 logical data block addressing – FUJITSU MAT3147NC/NP User Manual

Page 42

Advertising
background image

3-8

C141-E201

3.1.5 Format

capacity

The size of the usable area for storing user data on the IDD (format capacity) varies according to
the logical data block or the size of the spare sector area. Table 3.1 lists examples of the format
capacity when the typical logical data block length and the default spare area are used. The
following is the general formula to calculate the format capacity.

[Number of sectors of each zone] = [number of sectors per track

×

number of tracks per cell –

number of alternate spare sectors per cell]

×

[number of cells in the zone]

[Formatted capacity] = [total of sectors of all zones]

÷

[number of physical sectors in logical

block]

×

[logical data block length]

The following formula must be used when the number of logical data blocks are specified with the
parameter in the MODE SELECT or MODE SELECT EXTENDED command.

[Format capacity] = [logical data block length]

×

[number of logical data blocks]

The logical data block length, the maximum logical block address, and the number of the logical
data blocks can be read out by a READ CAPACITY, MODE SENSE, or MODE SENSE
EXTENDED command after initializing the disk medium.

Table 3.1

Format capacity

Model

Data block length

User blocks

Format capacity (GB)

MAT3300NC/NP 585,937,500

300.0 (*)

MAT3147NC/NP 287,277,984

147.0 (*)

MAT3073NC/NP

512

143,638,992 73.5

(*)

(*) 1GB=1,000,000,000 bytes

Note:

Total number of spare sectors is calculated by adding the number of spare sectors in each
primary cylinder and the number of sectors in the alternate cylinders.


3.2

Logical Data Block Addressing

Independently of the physical structure of the disk drive, the IDD adopts the logical data block
addressing as a data access method on the disk medium. The IDD relates a logical data block
address to each physical sector at formatting. Data on the disk medium is accessed in logical data
block units. The INIT specifies the data to be accessed using the logical data block address of that
data.

The logical data block addressing is a function whereby individual data blocks are given addresses
of serial binaries in each drive.