3 mode settings – FUJITSU MAT3147NC/NP User Manual

Page 82

Advertising
background image

5-10

C141-E201

5.3.3 Mode

settings

In addition to the previously described settings using setting terminals, the IDD is provided with several
mode settings. The mode settings are enabled by specifying the CHANGE DEFINITION command.
Table 5.7 lists the mode settings and their settings at factory shipment.

Refer to Section 3.1.4 of the SCSI Logical Interface Specifications for details of the command.

Table 5.7

Default mode settings (by CHANGE DEFINITION command)

Mode setting

Contents

SCSI level

SCSI-3

SYNCHRONOUS DATA TRANSFER REQUEST message
sending

Not sent from IDD

UNIT ATTENTION report mode

Reported

Reselection retry count

Not restricted

WIDE DATA TRANSFER REQUEST message sending

Not sent from IDD

Reselection time-out delay

250 ms

Spindle motor start delay time

0 sec (NP)

12 sec × SCSI ID (NC)

Advertising
This manual is related to the following products: