6.2 Troubleshooting

6.2.1 Controller and Heating Problems

Problem

Probable Causes

Corrective Action

A. Power cord is not plugged in or

circuit breaker is tripped.

A. Plug power cord in and verify

that circuit breaker is not
tripped.

Controller won't

activate. B. Controller or power supply

component or interface board has
failed.

B. If any of the components in the

power supply system (including
the transformer and interface
board) fail, power will not be
supplied to the controller and it
will not function. Call FASC.

A. Drain valve is open.

A. A drain safety switch prevents

the heating element from being
energized if the drain valve is
not fully closed. Verify that the
drain valve is fully closed.

Fryer does not heat.

B. One or more other components

have failed.

B. If the circuitry in the fryer

control system cannot determine
the frypot temperature, the
system will not allow the
element to be energized or will
de-energize the element. Call
FASC.