Frymaster YFPRE1817E User Manual

Page 29

Advertising
background image

6-3

Problem

Probable Causes

Corrective Action

Fryer repeatedly

cycles on and off

when first started.

Fryer is in melt-cycle mode.

This is normal behavior. Refer to
the separate YUM! Wingstreet
Controller Manual
.

Fryer heats until

high limit trips with

heat indicator ON.

Temperature probe or controller has
failed.

Turn fryer off and call FASC.

Fryer heats until

high limit trips

without heat

indicator ON.

Contactor or controller has failed.

Call FASC.

Fryer stops heating

with heat indicator

ON.

The high limit thermostat or
contactor has failed.

Call FASC.







6.2.2 Filtration

Problems

Problem

Probable Causes

Corrective Action

A. Power cord is not plugged in or

circuit breaker is tripped.

A. Verify that the power cord is

fully plugged in. If so, verify
that circuit breaker is not
tripped.

B. Pump motor has overheated

causing the thermal overload
switch to trip.

B. If the motor is too hot to touch

for more than a few seconds, the
thermal overload switch has
probably tripped. Allow the
motor to cool at least 45
minutes then press the Pump
Reset Switch.

Filter pump won't

start.

C. Blockage in filter pump.

Test: Close the drain valve and
pull the filter pan out from the
fryer. Activate the pump. If the
pump motor hums for a short time
and then stops, the probable cause
is blockage of the pump itself.

C. Pump blockages are usually

caused by sediment buildup in
the pump due to improperly
sized or installed filter paper
and failure to use the crumb
screen. Call FASC.

Advertising