FUJITSU MPB3052AT User Manual

Page 167

Advertising
background image

C141-E045-02EN

6 - 12

(2)

Alternate cylinder assignment

A defective sector is assigned to the spare sector in the alternate cylinder.

This processing is performed when the automatic alternate processing is performed.

Figure 6.8 shows an example where (physical) sector 5 is detective on head 0 in cylinder 0.

5

7

6

4

3

1

300

299

2

Index

Cylinder 0

Head 0

Head 0

Already

assigned

Defective

sector

4 alternate cylinders are provided for each head in zone 13 (inner side).

When an access request to sector 5 is specified, the device accesses the alternated sector in the
alternate cylinder instead of sector 5. When an access request to sectors next to sector 5 is
specified, the device seeks to cylinder 0, head 0, and continues the processing.

Defective sector is assigned to unassigned sector.

(unused)

Sector (logical)

Sector (physical)

Alternate
cylinder

2

1

4

3

6

7

299

298

Figure 6.8

Alternate cylinder assignment

Advertising